* CT Scanner *

1.General Electric Company:

2.GE light Speed 4 plus:

Specifications:
Octane console, H2 Gantry,
Tube Count 50mAs
Light Speed Plus Software Options:Thin Helical,Helical Tilt, Recon Plus, Samart Speed, SmartScore Pro, 3D, Smart Prep،VariViewer, AutomA, Power 440 .

3.GE light Speed 16:

GE CT Scanner Available
Model- Light Speed 16
MFG Year- 2005،Tube changed- Aug,2017
Tube mAs: 57629629،Tube scan sec: 260731.3
Complete system in good working condition

4.GE Bright speed Elite 16:

2008 Bright speed Elite /Tube count: 46,483 Scan/sec
SW Options:Helical Tilt,440mA Scan,Large Image Series Helios2 SmartSpeed 16 Slice,Direct 3D 90kVA Option,Direct MPR,

5.GE lightspeed VCT 64:

Tube Count: 23Mmas
،Software: 12HW14.6_SP1-1-1
Installed SW Options:Smart Prep Permanent AutomA Permanent
3000 Image Series Permanent Connect Pro Permanent
Exam Split Permanent Direct-MPR Permanent
NeuroFilter Permanent AutoFilterandTransfer Permanent
Patient-64-slice Permanent VCT-Hi-Power Permanent
SmartScore Pro Permanent CardIQ SnapShot Permanent
Sub-0.4-Second-Scan Permanent EKG Viewer Permanent
NoiseReductionFilter Permanent CardIQSnapShot-Cine Permanent

6.GE bright speed 16:

⦁ Condition: Used – Excellent
⦁ Brand: GE
⦁ Type: CT Scanner
⦁ Enlarging: image
⦁ Scale: display
⦁ Model: Brightspeed 16
⦁ Image : 1024 single
⦁ Rotation: 0.8sec to 1.0sec
⦁ Thickness: 10mm
⦁ Slice: 0.625 to
⦁ Slices: 16


Toshiba

1.Toshiba Aquilion ONE:

YOM : 10/2010
Slices : 320
Tube YOM : 12/2018
Tube Count : 150 000 scan sec.

2.Toshiba Asteoin KG:

3.Toshiba Asteoin Super4 (unit and part):

⦁ Brand: TOSHIBA
⦁ Type: CT Scanner
⦁ Model: ASTEION Super4
⦁ Scan fields of view (cm) (SCANNER GANTRY): 18,24,32,40,50
⦁ Spot, Mm: 0.8
⦁ Capacity: MHU
⦁ Tube Focal: 0.9 x
⦁ Tube heat:  6.3

4.Toshiba Aquilion 16 slice:

⦁ MPN: TSX-101A
⦁ Dynamic Scan Pace : 200 scans/100 sec
⦁ Heat Dissipation Rate, Hu/Min : 1,386,000 max
⦁ Heat Storage, Hu : 7,500,000
⦁ Kvp Range : 80,100,120, 135
⦁ Ma Range : 1010-50 in 5 mA steps
⦁ Matrixes, Pixels : 1280 x 1024
⦁ Max Scan Time, Sec : 100
⦁ Monitor: 18′ LCD color x 2
⦁ Output, Kw : 60
⦁ Pitch : 0.8-120 mm/sec couch-top speed
⦁ Slices: 8
⦁ Tube Focal Spot, Mm : 1.6 x 1.4, 0.9 x 0.8 (IEC standard)

5.Toshiba Activision 16:

6.Toshiba Aquilion 64:

⦁ Gantry diameter: 72 cm
⦁ Generator:  X-ray generator kV range: 80, 100, 120 and 135 kVp
⦁ Maximum scan range (cm): 1800 mm cm
⦁ Minimum rotation speed: 0.4
⦁ Slices: 4
⦁ Tube heat capacity: 4.0 MHU

Philips CT

.1Philips brilliance 64:

⦁ Type: CT Scanner
⦁ MPN: 64-slice
⦁ X-Ray Tube: 8.0 mhu

.2Philips brilliance 16:

⦁ MPN: 16-slice
⦁ Hd Capacity, Gb : 292
⦁ Heat Storage, Hu : 5.0 MHU/8.0 MHU
⦁ Scantime: 0.4 sec* full gantry rotation
⦁ Slices: 16
⦁ Tube Cooling : Oil/air
⦁ Tube Focal Spot, Mm : 0.5 x 1 small, 1 x 1 large
⦁ Type : Multislice

Siemens CT

1.Siemens Sensation 4:

⦁ MPN: 07005502
⦁ Slices: 4
⦁ Tube: Dura 532 / Akron B
⦁ Tube Count: 
⦁ Year of Manufacture: 2003 refurbished by SIEMENS® 2010

2.Siemens sensation 16:

⦁ Tube: DURA Akron Q
⦁ Warranty: 1 Year
⦁ X-Ray Tube: Akron Q

Hitachi CT

1.Hitachi ECLOS 4 ( unit and parts):

2.Hitachi ECLOS 16:

⦁ Gantry diameter: 70 cm
⦁ Maximum beam width (cm): 2 cm
⦁ Rotation: Other rotation speed options: 1.0, 1.5, 2.0, 3.0 seconds
⦁ Slices: 8
⦁ Table Movement Horizontal Range: 186 cm
⦁ Table Movement Vertical Range: 42 to 100 cm
⦁ X-Ray Tube: Heat Capacity: 5.0 MHU

PET CT

Philips Biograph 16:

Share: